| Unit of measurement | Iso 100-2E | ||
| Connected air duct size | mm | 100 | |
| Phases | - | 1 | |
| Minimum supply voltage | V | 230 | |
| Maximum supply voltage | V | 230 | |
| Power supply frequency | Hz | 50 | |
| Rated power | W | 130 | |
| Unit current | A | 0.6 | |
| Maximum airflow | m³/h | 425 | |
| Rotation speed at 50hz | - | 2870 | |
| Sound pressure level LpA at 3 m | dB(A) | 36 | 1 |
| Weight | kg | 4.22 | |
| Transported air temperature (max) | °С | 40 | |
| Transported air temperature (min) | °С | -25 | |
| Ingress protection rating | - | IPX2 | |
| Ingress protection rating of the drive | - | IP44 | |
| Impeller material | - | Galvanized steel | |
| Trademark | Blauberg | |||||
| Model | Iso 100-2E | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -51 | A+ | -23.9 | C | -8.4 | F | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 380 | |||||
| Electric power input (W) | 125 | |||||
| Reference flow rate (m³/s) | 0.074 | |||||
| Reference pressure difference (Pa) | 50 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.329 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Declared typology | RVU UVU | |||||
| Sound power level (dB(A)) | 56 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 174 | 174 | 174 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Blauberg CDT E1.8 |
|
Thyristor speed controller |
| Name | Photo | Description |
|---|---|---|
| Blauberg HSE / HSI 1.5 |
|
Sensors |
| Blauberg TE / TI 1.5 |
|
Timers |
| Blauberg LSE / LSI 1.5 |
|
Sensors |
| Blauberg IRSE / IRSI 1.5 |
|
Sensors |